6W Wall Mount Type YS6U
6W Wall Mount Type YS6U
Rated Power: 6W
Input: 100-240V AC, 50 / 60Hz
Standby Power: ≤0.1W
Protection: Short Circuit, OCP, OVP
Output: 5-36V
Inrush Current: 65 Amps max. at 230VAC/50Hz, full load
Rated Power: 6W
Input: 100-240V AC, 50 / 60Hz
Standby Power: ≤0.1W
Protection: Short Circuit, OCP, OVP
Output: 5-36V
Inrush Current: 65 Amps max. at 230VAC/50Hz, full load
Input:100-240VAC 50/60Hz
Output Voltage: 5V-30V DC
Rated Power: 6W max.
Features :
1. Univeral AC input/ Full range
2. Medical safety approved(2×MOPP)
3. Leakage Current: <50μA
4. Extremely low leakage current
5. Protection: Overload/Over voltage/Short circuit
6. Withstand voltage: 4KV
7. Life Warranty: 3 years
Model: | YS6-0501200U | YS6-0601000U | YS6-0750800U | YS6-0901000U | YS6-0501000U | YS6-0501000U |
Power: | 6W | |||||
Input: | AC100-240V | |||||
Output Voltage: | 5V DC | 6V DC | 7.5V DC | 9V DC | 12V DC | 24V DC |
Output Current: | 0-1.2A | 0-1A | 0-0.8A | 0-0.6A | 0-0.5A | 0-0.25A |
Inrush Current: | 65 Amps max. at 240VAC/50Hz, full load | |||||
Leakage Current: | <50μA | |||||
No Load Power Consumption : | <0.5W | |||||
Protections: | Short Circuit /Over Current /Over Voltage/over-temperature protection | |||||
Short Circuit Protection (SCP): | Protection to Zero Voltage | |||||
Over Voltage Protection (OVP): | ≤Vout*150% | |||||
Over Current Protection (OCP): | 110%-180% | |||||
Withstand voltage: | I/P-O/P 4kVAC | |||||
Working TEMP.: | -20°C-50°C | |||||
EMC standards: | EN55011 class B,EN61000-3-2,3EN61000-4-2,3,4,5,6,8,11, EN61204-3, EN60601-1-2 medical level,FCC Part 15 class B, EAC TP TC 020 | |||||
Safety standards: | ANSI/AAMI ES60601-1/ES60601-1-11,CAN/CSA-C22,TUV EN60601-1-11,EAC TP TC 004 approved | |||||
Dimension: | 59*39*36.5mm |