The RCD plug continuously monitors the power supply to an electrical appliance and cuts off the power within 40 milliseconds if an earth current fault is detected. This is fast enough to prevent a fatal electric shock. This plug is an ideal way to protect yourself when using portable electrical tools such as lawnmowers and drills.
Electrical appliances can become dangerous if the wiring becomes loose, their power cords become damaged or if they get wet. Not only power tools and lawnmowers can cause electrocution–it is also possible if fingers, wet hair or other conductive bodies enter the appliance. In all these cases the RCD plug is a must. RCD plugs are the simplest way of power protection for in and around the home. Ideally, you would use an RCD plug with any electrical appliance. Please note, these products are not suitable for pond pumps and other pond equipment as when these are removed the installation is unprotected.
1.RCD03G is applicable to electrical appliance of Germany
2.Reduce the risk of electric shock
3.Use with mowers, strimmers and other portable tools
4.Plugs in to a standard 16-AMP socket
5.Portable – can be moved between socket outlets
6.Separates test and reset buttons, and manual reset
7.Mechanical flag to indicate contact position
8.Robust Case
9.TUV Rheinland-GS approved
10.CE approved
11.RoHS2.0 approved
Main Technical Specifications
|
l Rated Voltage:
|
220-240VAC~/50Hz
|
l Max. Load Current:
|
16A
|
l Rated trip Current:
|
10mA
|
l Leakage no tripping Current:
|
5mA
|
l Max Tripping Time:
|
40mS
|
l Work Environment Temperature:
|
-25°C~+40°C
|
l Protection Class:
|
IP44
|
l Non-Latching Operation
|
|
l Flexible Cord
|
H05RN3G1.0; H05VV-F3G1.0/1.5;H05RR3G1.5
|
l Standard:
|
IEC61540
|
l Unit Size:
|
106*49*65mm
|
Packing Details
|
l Packing:
|
White box
|
l Meas.:
|
45cm×26cm×30cm (50PCS/CTN)
|
l N.W.:
|
9KG
|
l G.W.
|
10KG
|
Certification:GS,CE,RoHS2.0,PAHS
|