lf

LF15

LF15 – Air Compressor Pressure Switch

0.3~1.2MPa

MediumAir, non-flammable or non-hazardous, non-corrosive gas
Pressure regulation range0.3-1.2Mpa
Differential pressure adjustment range0.15-0.45Mpa
Factory settingsStarting pressure and disconnecting pressure can be set according to customer requirements
Pressure setpoint error≤ 5% (working pressure value)
Maximum working pressure1.2Mpa
Rated voltage, current and frequency120VAC/240VAC, 26A/20A, 50HZ/60HZ
Contact modeNormally closed
Interface formSingle way internal thread,
single way external thread,
double way internal and external thread,
four-way internal thread
Interface threadNpt1/4, R1/4, G1/4 (can be customized)
Unloading valveNone / Yes
Direction of unloading valveThe direction and angle can be selected according to customer requirements
Inner diameter of relief valveØ6.0mm, Ø6.4mm, Ø6.5mm (can be customized)
Manual formNo / handle
working temperature-20°C-80°C
Mechanical life100,000 operations
Electrical life30000 operations
Withstand voltageNo breakdown at 2500V for 1 minute
Installation modeVertical/horizontal installation
Degree of protectionIP20

LF15 series pressure switch is used to adjust the pressure in the air tank of the air compressor to make it operate between two preset pressure values.

The pressure switch, with relief valve, can prevent the air compressor from overload starting, and the additional handle can be used to manually cut off the power supply of the compressor. Greater arc extinguishing current.

The four-way base interface can make the installation of supporting components such as safety valves and pressure gauges easier.