ART. 210 for Indoor Catalytic Heater

ART. 210 for Indoor Catalytic Heater
Safety gas valves for Catalytic heater.
Safety gas valves for Catalytic heater.
1. Gas inlet
2. Spindle for knob
3. Max. working pressure (7kPa for CE and 1/2 psi for CSA)
4. Manufacturer and product family
5. Fitting thermocouple
6. Gas flow direction
7. Gas outlet
8. Production date (four digit date code year/week), and code
1.2 – Technical properties
CE Approval: in accordance to GAR EU/2016/426 – Certificate N°: CE-0085AQ0789
Working temperature: 0°C – 150°C
Max working pressure: 7kPa (65 mbar)
Working angular rotation: 90°- 180° – 210° – 270° (see technical drawing here below)
Position of maximum: see technical drawing here below
Gas inlet connection: cylindrical thread – with hose tail
Gas outlet connection: various
Knob shaft connection: max. Ø 8
Fitted with: safety device for flame control
Applications: mobile radiant appliances
Group: 2
Kind of gas: I, II, III
Tap endurance test: 10.000 (CE)
Safety device endurance test: 10.000 (CE)