ART. 712 for Oven & Grill
ART. 712 for Oven & Grill
Two ways adjustable thermostatic safety gas valve.
Two ways adjustable thermostatic safety gas valve.
1. Gas Inlet (Ø 16, Ø 18 tube or others) 2. Spindle for knob
3. Fitting thermocouple
4. Thermostatic feeler
5. Gas flow direction
6. Gas outlet
7. Markings: Model (712), Production date (year/week or production batc), range of temperature 8. Low adjusting screw
9. Max. working pressure (7kPa for CE and 1/2PSI for CSA)
10. Manufacturer and product family
11. CE marking
1.2 – Technical properties
CE Approval: Accordance to GAR EU/2016/426 – Certificate N°: 51CP4480
Working temperature: 0°C – 150°C
Maximum working temperature is reduced to 80° when nitrile elastomer gaskets are used.
Max working pressure:7kPa (65 mbar)
Working angular rotation: 231°
Gas inlet connection: Clamp-on for Ø16 o Ø18 manifold (other on request)
Gas outlet connection: Various
Knob shaft connection: Max. Ø8
With adjustable low rate screw With safety device for flame control
Applications: Cooking
Group: 2
Assembling position: Any
Class of the device:B
Kind of gas: I, II, III
Tap endurance test: 10.000 cycles
Static functioning: 48 hours at 150°C – 48 hours at 0°C
Max. Setting temperature: 300°C
Temp. adjustment field: 100 – 300°C (differential 150°C – max 175°C)
Temp. tolerance: ± 10°C
Operation torque: ≤ 0,4 Nm
Operation force: ≤ 35 N
Mechanical differential: 6° A
Max. temp. of the bulb: 315°C
Xp1_Xp2: 95% of 500* L/h
Reduced flow rates: declared value + 5 %; max. 100* L/h * = (Air – ΔP 2,5 mbar – Inlet pressure: 20 mbar)