ART. 112 for Oven & Grill
ART. 112 for Oven & Grill
Two ways clamp-on adjustable safety gas valve.
Two ways clamp-on adjustable safety gas valve.
1. Gas inlet (Tube Ø 16 – Ø 10 – Ø 8)
2. Spindle for knob
3. Max. working pressure (7kPa for CE and 1/2 psi for CSA)
4. Manufacturer
5. Fitting thermocouple
6. Gas flow direction
7. First gas outlet (oven)
8. Second gas outlet (grill)
9. Low adjusting screw first outlet
10. Production date (year/week or production batch), valve code and max. temperature
1.2 – Technical properties
CE Approval:
Working temperature: 0 °C -150°C
Max working pressure: 7kPa (65 mbar)
Working angular rotation first outlet: +160°
Working angular rotation second outlet: – 90°
Position of maximum: 90°
Gas inlet connection: clamp-on for Ø 16, Ø 10 and Ø 8 manifold
Gas outlet connection: 1⁄4 Gas
Knob shaft connection: max. Ø 8
Fitted with: adjustable low rate screw
Fitted with: safety device for flame control
Applications: cooking
Group: 2
Kind of gas: I, II, III
Tap endurance test: 40.000 (CE) – 10.000 (CSA)
Safety device endurance test : 10.000 (CE) – 6.000 (CSA)
in accordance to GAR EU/2016/426 – Certificate N°: CE-0085AQ0789
Flow rates manifold: > Ø16
Flow rate index 1° outlet: (Δp=2,5 mbar): > 95% of 0,289 m^3/h Flow rate index 2° outle: (Δp=2,5 mbar): > 95% of 0,277 m^3/h