Applications

Oxi-pilots

  • Gas Taps

    900 Series - ODS Oxypilot

    • The device stops the supply of gas, when the level of carbon dioxide (CO2) in the atmosphere reaches a value between 0.8% and 1.5% in volume
    • Functioning guaranteed up to 2000 mt above the sea level
    • Specific personalization for each device made inside an hermetically sealed chamber which is manufactured according to EN 449 standard
    • The same pilot can connect to either 4mm or 6 mm diameter pipework, with the use of an adaptor olive
    • Various thermocouple options available on request
    • Typical applications where indoor heating appliances are use or where a minimum oxygen level or high carbon dioxide levels are a concern. Gas fires, Patio Heaters etc.
    • Gas rate controlled via a ruby injector
    • Suitable for a variety of gases for most countries
    • Can be supplied either assembled or in component parts
    • Standard European mounting bracket
  • Gas Taps

    699 Series - Pilot Burner

    • Provides a sentinel pilot flame for main burner ignition and re-ignition.
    • The same pilot can connect to either 4mm or 6 mm diameter pipework, with the use of an adaptor olive
    • Interchangeable injectors
    • Various thermocouple options available on request
    • Typical applications are water heating and storage heating
    • Suitable for a variety of gases for most countries
    • Can be supplied either assembled or in component parts
    • Common European mounting bracket

    Please contact us to arrange a visit from one of our application engineers or to request a competitive quotation.